Including 1% procurement surcharge. No responsibility for the information!
+++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62 +++ 17.11.2017 + AL 218.63 + CU 588.20 +++ 16.11.2017 + AL 215.27 + CU 580.37 +++ 15.11.2017 + AL 217.13 + CU 594.03
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

EMC connecting cable 2XSL(St)CYv

2XSL(St)CYv
flame retardant acc. IEC 60332-1-2 screened cable cable to a large extent oil resistant max. permitted temperature at conductor 90 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

screened cable screened cable

cable to a large extent oil resistant cable to a large extent oil resistant

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Conductor materialbare copper
Conductor classclass 5 = fine stranded
InsulationXLPE
Core wrappingplastic foil
Screenaluminium foil + copper braid, tinned
Screen coverage75 %
Sheathing materialPVC, enforced
Colour outer sheathblack
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
Oil-resistantEN 60811-2-1
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-30 - +70 °C
Permitted outer cable temperature, in motion/during installation-5 - +70 °C
Bending radius, fixed installation10 x DA
Bending radius, moving application20 x DA

The cable has been developed for connecting motors to inverse rectifiers under consideration of EMC-requirements. It may be used under medium mechanical stress for fixed installations and temporary movement. Also for outdoor installation, but not for direct burial. The cable is resistant to most usual oil and grease.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
034455 EMV 2XSL(St)CYv-JB 04X1,5 0,6/1 kV SW 95.0 212.0
034456 EMV 2XSL(St)CYv-JB 04X2,5 0,6/1 kV SW 150.0 270.0
034457 EMV 2XSL(St)CYv-JB 04X4 0,6/1 kV SW 238.0 362.0
034458 EMV 2XSL(St)CYv-JB 04X6 0,6/1 kV SW 320.0 582.0
034459 EMV 2XSL(St)CYv-JB 04X10 0,6/1 kV SW 533.0 794.0
035909 EMV 2XSL(St)CYv-JB 04X35 0,6/1 kV SW 1663.0 2402.0
034460 EMV 2XSL(St)CYv-JB 03X16 + 03G2,5 0,6/1 kV SW 723.0 835.0
034461 EMV 2XSL(St)CYv-JB 03X25 + 03G4 0,6/1 kV SW 1204.0 1404.0
034462 EMV 2XSL(St)CYv-JB 03X35 + 03G6 0,6/1 kV SW 1535.0 1813.0
034463 EMV 2XSL(St)CYv-JB 03X50 + 03G10 0,6/1 kV SW 2208.0 2501.0
034464 EMV 2XSL(St)CYv-JB 03X70 + 03G10 0,6/1 kV SW 2980.0 3112.0
034465 EMV 2XSL(St)CYv-JB 03X95 + 03G16 0,6/1 kV SW 3953.0 4492.0
034466 EMV 2XSL(St)CYv-JB 03X120 + 03G16 0,6/1 kV SW 5007.0 5301.0
034467 EMV 2XSL(St)CYv-JB 03X150 + 03G25 0,6/1 kV SW 5488.0 6097.0
034468 EMV 2XSL(St)CYv-JB 03X185 + 03G35 0,6/1 kV SW 6969.0 7597.0
034469 EMV 2XSL(St)CYv-JB 03X240 + 03G50 0,6/1 kV SW 9123.0 9875.0
034470 EMV 2XSL(St)CYv-JB 03X300 + 03G50 0,6/1 kV SW 10690.0 11530.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.