Including 1% procurement surcharge. No responsibility for the information!
+++ 23.11.2017 + AL 217.19 + CU 598.52 +++ 22.11.2017 + AL 215.65 + CU 595.88 +++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62 +++ 17.11.2017 + AL 218.63 + CU 588.20
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

Medium voltage cable N2XSH

N2XSH
flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C min. installation temperature +5 °C installation in free air only with UV-protection (cable not UV-resistant)

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

min. installation temperature +5 °C min. installation temperature +5 °C

installation in free air only with UV-protection (cable not UV-resistant) installation in free air only with UV-protection (cable not UV-resistant)

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0276-622
Conductor materialbare copper
Conductor classclass 2 = stranded
InsulationXLPE DIX8
Sheathing materialFRNC-compound HM4
Colour outer sheathblack
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
For outdoor useyes
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed70 °C
Permitted outer cable temperature, in motion/during installation-5 - +70 °C
Bending radius, fixed installation15 x DA

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
013511 N2XSH 01X50/16 6/10 kV SW 662.0 1050.0
012736 N2XSH 01X70/16 6/10 kV SW 854.0 1300.0
012083 N2XSH 01X95/16 6/10 kV SW 1094.0 1561.0
012764 N2XSH 01X120/16 06/10 kV SW 1334.0 1688.0
012075 N2XSH 01X150/16 6/10 kV SW 1723.0 2290.0
013758 N2XSH 01X150/25 6/10 kV SW 1723.0 3250.0
012737 N2XSH 01X185/25 6/10 kV SW 2059.0 2550.0
012954 N2XSH 01X240/25 6/10 kV SW 2587.0 3106.0
012955 N2XSH 01X300/25 6/10 kV SW 3163.0 3750.0
012956 N2XSH 01X400/35 6/10 kV SW 4234.0 4660.0
012634 N2XSH 01X400/75 6/10 kV SW 4620.0 5194.0
012765 N2XSH 01X500/35 6/10 kV SW 5194.0 5200.0
012635 N2XSH 01X630/25 6/10 kV SW 6442.0 8697.0
013813 N2XSH 01X35/16 12/20 kV SW 518.0 1080.0
013814 N2XSH 01X50/16 12/20 kV SW 662.0 1240.0
013636 N2XSH 01X70/16 12/20 kV SW 854.0 1500.0
013490 N2XSH 01X95/16 12/20 kV SW 1094.0 1730.0
013491 N2XSH 01X185/25 12/20 kV SW 2059.0 2810.0
012957 N2XSH 01X240/25 12/20 kV SW 2587.0 3400.0
012958 N2XSH 01X400/35 12/20 kV SW 4234.0 4950.0
013797 N2XSH 01X70/16 18/30 kV SW 854.0 2000.0
013791 N2XSH 01X240/50 18/30 kV SW 2869.0 3900.0
013792 N2XSH 01X240/70 18/30 kV SW 3095.0 4100.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.