Including 1% procurement surcharge. No responsibility for the information!
+++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62 +++ 17.11.2017 + AL 218.63 + CU 588.20 +++ 16.11.2017 + AL 215.27 + CU 580.37 +++ 15.11.2017 + AL 217.13 + CU 594.03
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

Instrumentation cable RE-2X(St)YSWAY-fl PiMF

RE-2X(St)YSWAY-fl PiMF
flame retardant acc. IEC 60332-3-24 screened cable cable suitable for direct burial cable with rodent protection (optical fibre) not for application in power circuits cable to a large extent oil resistant min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

screened cable screened cable

cable suitable for direct burial cable suitable for direct burial

cable with rodent protection (optical fibre) cable with rodent protection (optical fibre)

not for application in power circuits not for application in power circuits

cable to a large extent oil resistant cable to a large extent oil resistant

min. installation temperature -5 °C min. installation temperature -5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Direct burialyes
Conductor materialbare copper
Conductor classclass 2, 7-wired construction
InsulationXLPE
Stranding unitpair
Strandinglayers
Core wrappingplastic foil
Material inner sheathPVC
Screenplastic coated aluminium foil + copper drain wire, tinned
Armourround or flat steel wires, galvanized
Sheathing materialPVC
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
UV-resistantyes
Oil-resistantyes
Permitted outer cable temperature, fixed-30 - +70 °C
Permitted outer cable temperature, in motion/during installation-5 - +50 °C
Bending radius, fixed installation10 x DA
Insulation resistance5000 MOhmxkm
Specific inductivity1 mH/km

For data communication with transmission rates up to 200 kBit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in earth.The types with blue outer sheath are suitable for intrinsically safe installation -Ex i- in hazardous areas. Core identification: black-white(-orange) with sequential numbering

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
101278 RE-2X(St)YSWAY-fl PiMF 06X2X0,5 SW IEC 332-3-24 90.0 485.0
101517 RE-2X(St)YSWAY-fl PiMF 02X2X0,75 SW IEC 332-3-24 47.0 355.0
101518 RE-2X(St)YSWAY-fl PiMF 04X2X0,75 SW IEC 332-3-24 82.0 420.0
101529 RE-2X(St)YSWAY-fl PiMF 08X2X0,75 SW IEC 332-3-24 160.0 610.0
101530 RE-2X(St)YSWAY-fl PiMF 12X2X0,75 SW IEC 332-3-24 237.0 920.0
101790 RE-2X(St)YSWAY-fl PiMF 24X2X0,75 SW IEC 332-3-24 470.0 1438.0
101675 RE-2X(St)YSWAY-fl PiMF 04X2X1 SW IEC 332-3-24 103.0 525.0
101158 RE-2X(St)YSWAY-fl PiMF 02X2X1,3 SW IEC 332-3-24 68.0 384.0
101273 RE-2X(St)YSWAY-fl PiMF 04X2X1,3 SW IEC 332-3-24 124.0 530.0
101189 RE-2X(St)YSWAY-fl PiMF 08X2X1,3 SW IEC 332-3-24 239.0 973.0
101320 RE-2X(St)YSWAY-fl PiMF 12X2X1,3 SW IEC 332-3-24 353.0 1150.0
101491 RE-2X(St)YSWAY-fl PiMF 16X2X1,3 SW IEC 332-3-24 468.0 719.0
101191 RE-2X(St)YSWAY-fl PiMF 24X2X1,3 SW IEC 332-3-24 697.0 2264.0
101692 RE-2X(St)YSWAY-fl PiMF 02X2X1,5 SW IEC 332-3-24 72.0 420.0
101484 RE-2X(St)YSWAY-fl PiMF 04X2X1,5 SW IEC 332-3-24 139.0 570.0
101734 RE-2X(St)YSWAY-fl PiMF 05X2X1,5 SW IEC 332-3-24 173.0 813.0
101693 RE-2X(St)YSWAY-fl PiMF 06X2X1,5 SW IEC 332-3-24 206.0 915.0
101276 RE-2X(St)YSWAY-fl PiMF 08X2X1,5 SW IEC 332-3-24 281.0 994.0
101694 RE-2X(St)YSWAY-fl PiMF 10X2X1,5 SW IEC 332-3-24 341.0 1700.0
101435 RE-2X(St)YSWAY-fl PiMF 12X2X1,5 SW IEC 332-3-24 401.0 1338.0
101515 RE-2X(St)YSWAY-fl PiMF 24X2X1,5 SW IEC 332-3-24 811.0 2890.0
101279 RE-2X(St)YSWAY-fl PiMF 06X2X0,5 BL IEC 332-3-24 90.0 485.0
101519 RE-2X(St)YSWAY-fl PiMF 02X2X0,75 BL IEC 332-3-24 47.0 355.0
101520 RE-2X(St)YSWAY-fl PiMF 04X2X0,75 BL IEC 332-3-24 82.0 420.0
101531 RE-2X(St)YSWAY-fl PiMF 08X2X0,75 BL IEC 332-3-24 160.0 610.0
101532 RE-2X(St)YSWAY-fl PiMF 12X2X0,75 BL IEC 332-3-24 237.0 920.0
101791 RE-2X(St)YSWAY-fl PiMF 24X2X0,75 BL IEC 332-3-24 470.0 1438.0
101676 RE-2X(St)YSWAY-fl PiMF 04X2X1 BL IEC 332-3-24 103.0 525.0
101159 RE-2X(St)YSWAY-fl PiMF 02X2X1,3 BL IEC 332-3-24 68.0 384.0
101274 RE-2X(St)YSWAY-fl PiMF 04X2X1,3 BL IEC 332-3-24 124.0 530.0
101190 RE-2X(St)YSWAY-fl PiMF 08X2X1,3 BL IEC 332-3-24 239.0 973.0
101319 RE-2X(St)YSWAY-fl PiMF 12X2X1,3 BL IEC 332-3-24 353.0 1150.0
101492 RE-2X(St)YSWAY-fl PiMF 16X2X1,3 BL IEC 332-3-24 468.0 719.0
101194 RE-2X(St)YSWAY-fl PiMF 24X2X1,3 BL IEC 332-3-24 697.0 1779.0
101695 RE-2X(St)YSWAY-fl PiMF 02X2X1,5 BL IEC 332-3-24 72.0 420.0
101485 RE-2X(St)YSWAY-fl PiMF 04X2X1,5 BL IEC 332-3-24 139.0 570.0
101735 RE-2X(St)YSWAY-fl PiMF 05X2X1,5 BL IEC 332-3-24 173.0 813.0
101696 RE-2X(St)YSWAY-fl PiMF 06X2X1,5 BL IEC 332-3-24 206.0 915.0
101277 RE-2X(St)YSWAY-fl PiMF 08X2X1,5 BL IEC 332-3-24 281.0 994.0
101697 RE-2X(St)YSWAY-fl PiMF 10X2X1,5 BL IEC 332-3-24 341.0 1700.0
101436 RE-2X(St)YSWAY-fl PiMF 12X2X1,5 BL IEC 332-3-24 401.0 1338.0
101516 RE-2X(St)YSWAY-fl PiMF 24X2X1,5 BL IEC 332-3-24 811.0 2890.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.