Including 1% procurement surcharge. No responsibility for the information!
+++ 23.11.2017 + AL 217.19 + CU 598.52 +++ 22.11.2017 + AL 215.65 + CU 595.88 +++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62 +++ 17.11.2017 + AL 218.63 + CU 588.20
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

Instrumentation cable RE-2Y(St)Yv PiMF

RE-2Y(St)Yv PiMF
flame retardant acc. IEC 60332-1-2 screened cable cable suitable for direct burial not for application in power circuits installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

screened cable screened cable

cable suitable for direct burial cable suitable for direct burial

not for application in power circuits not for application in power circuits

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Direct burialyes
Conductor materialbare copper
Conductor classclass 2, 7-wired construction
Insulationpolyethylene
Stranding unitpair
Screen over stranding unitplastic coated Al-foil + copper drain wire, tinned
Screen over strandplastic coated Al-foil + copper drain wire, tinned
Sheathing materialPVC, enforced
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
For outdoor useyes
Permitted outer cable temperature, fixed-5 - +50 °C
Permitted outer cable temperature, in motion/during installation-30 - +70 °C
Bending radius, fixed installation7.5 x DA
Insulation resistance5000 MOhmxkm
Specific inductivity0.75 mH/km

For data communication with transmission rates up to 200 kBit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, in outdoor and direct burial in earth.The types with blue outer sheath are suitable for intrinsically safe installation -Ex i- in hazardous areas.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
100869 RE-2Y(St)Yv PiMF 02X2X0,5 SW IEC 332-1 35.0 130.0
100870 RE-2Y(St)Yv PiMF 04X2X0,5 SW IEC 332-1 60.0 168.0
100871 RE-2Y(St)Yv PiMF 06X2X0,5 SW IEC 332-1 82.0 215.0
100872 RE-2Y(St)Yv PiMF 08X2X0,5 SW IEC 332-1 121.0 249.0
100873 RE-2Y(St)Yv PiMF 10X2X0,5 SW IEC 332-1 136.0 254.0
100874 RE-2Y(St)Yv PiMF 12X2X0,5 SW IEC 332-1 161.0 349.0
100875 RE-2Y(St)Yv PiMF 16X2X0,5 SW IEC 332-1 212.0 427.0
100876 RE-2Y(St)Yv PiMF 20X2X0,5 SW IEC 332-1 262.0 491.0
100877 RE-2Y(St)Yv PiMF 24X2X0,5 SW IEC 332-1 313.0 599.0
100878 RE-2Y(St)Yv PiMF 36X2X0,5 SW IEC 332-1 465.0 843.0
100879 RE-2Y(St)Yv PiMF 48X2X0,5 SW IEC 332-1 616.0 1110.0
100880 RE-2Y(St)Yv PiMF 02X2X0,75 SW IEC 332-1 41.0 150.0
100881 RE-2Y(St)Yv PiMF 04X2X0,75 SW IEC 332-1 76.0 200.0
100882 RE-2Y(St)Yv PiMF 06X2X0,75 SW IEC 332-1 112.0 265.0
100883 RE-2Y(St)Yv PiMF 08X2X0,75 SW IEC 332-1 147.0 320.0
100884 RE-2Y(St)Yv PiMF 10X2X0,75 SW IEC 332-1 183.0 400.0
100885 RE-2Y(St)Yv PiMF 12X2X0,75 SW IEC 332-1 219.0 430.0
100886 RE-2Y(St)Yv PiMF 16X2X0,75 SW IEC 332-1 290.0 550.0
100887 RE-2Y(St)Yv PiMF 20X2X0,75 SW IEC 332-1 361.0 650.0
100888 RE-2Y(St)Yv PiMF 24X2X0,75 SW IEC 332-1 432.0 790.0
100889 RE-2Y(St)Yv PiMF 02X2X1,3 SW IEC 332-1 68.0 183.0
100890 RE-2Y(St)Yv PiMF 04X2X1,3 SW IEC 332-1 124.0 268.0
100891 RE-2Y(St)Yv PiMF 06X2X1,3 SW IEC 332-1 178.0 360.0
100892 RE-2Y(St)Yv PiMF 08X2X1,3 SW IEC 332-1 239.0 441.0
100893 RE-2Y(St)Yv PiMF 12X2X1,3 SW IEC 332-1 353.0 559.0
100894 RE-2Y(St)Yv PiMF 16X2X1,3 SW IEC 332-1 468.0 788.0
100895 RE-2Y(St)Yv PiMF 24X2X1,3 SW IEC 332-1 697.0 1103.0
100896 RE-2Y(St)Yv PiMF 02X2X0,5 BL IEC 332-1 35.0 130.0
100897 RE-2Y(St)Yv PiMF 04X2X0,5 BL IEC 332-1 60.0 168.0
100898 RE-2Y(St)Yv PiMF 06X2X0,5 BL IEC 332-1 82.0 215.0
100899 RE-2Y(St)Yv PiMF 08X2X0,5 BL IEC 332-1 121.0 249.0
100900 RE-2Y(St)Yv PiMF 10X2X0,5 BL IEC 332-1 136.0 254.0
100901 RE-2Y(St)Yv PiMF 12X2X0,5 BL IEC 332-1 161.0 349.0
100902 RE-2Y(St)Yv PiMF 16X2X0,5 BL IEC 332-1 212.0 427.0
100903 RE-2Y(St)Yv PiMF 20X2X0,5 BL IEC 332-1 262.0 491.0
100904 RE-2Y(St)Yv PiMF 24X2X0,5 BL IEC 332-1 313.0 599.0
100905 RE-2Y(St)Yv PiMF 36X2X0,5 BL IEC 332-1 465.0 843.0
100906 RE-2Y(St)Yv PiMF 48X2X0,5 BL IEC 332-1 616.0 1110.0
100907 RE-2Y(St)Yv PiMF 02X2X0,75 BL IEC 332-1 41.0 150.0
100908 RE-2Y(St)Yv PiMF 04X2X0,75 BL IEC 332-1 76.0 200.0
100909 RE-2Y(St)Yv PiMF 06X2X0,75 BL IEC 332-1 112.0 265.0
100910 RE-2Y(St)Yv PiMF 08X2X0,75 BL IEC 332-1 147.0 320.0
100911 RE-2Y(St)Yv PiMF 10X2X0,75 BL IEC 332-1 183.0 400.0
100912 RE-2Y(St)Yv PiMF 12X2X0,75 BL IEC 332-1 219.0 430.0
100913 RE-2Y(St)Yv PiMF 16X2X0,75 BL IEC 332-1 290.0 550.0
100914 RE-2Y(St)Yv PiMF 20X2X0,75 BL IEC 332-1 361.0 650.0
100915 RE-2Y(St)Yv PiMF 24X2X0,75 BL IEC 332-1 432.0 790.0
100916 RE-2Y(St)Yv PiMF 02X2X1,3 BL IEC 332-1 68.0 183.0
100566 RE-2Y(St)Yv PiMF 04X2X1,3 BL IEC 332-1 124.0 220.0
100917 RE-2Y(St)Yv PiMF 06X2X1,3 BL IEC 332-1 178.0 360.0
100919 RE-2Y(St)Yv PiMF 08X2X1,3 BL IEC 332-1 239.0 441.0
100920 RE-2Y(St)Yv PiMF 12X2X1,3 BL IEC 332-1 353.0 559.0
100921 RE-2Y(St)Yv PiMF 16X2X1,3 BL IEC 332-1 468.0 788.0
100922 RE-2Y(St)Yv PiMF 24X2X1,3 BL IEC 332-1 697.0 1103.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289