Instrumentation cable RE-2X(St)YSWAY FR

RE-2X(St)YSWAY FR
flame retardant acc. IEC 60332-3-24 screened cable cable suitable for direct burial cable with rodent protection (optical fibre) not for application in power circuits cable to a large extent oil resistant min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

screened cable screened cable

cable suitable for direct burial cable suitable for direct burial

cable with rodent protection (optical fibre) cable with rodent protection (optical fibre)

not for application in power circuits not for application in power circuits

cable to a large extent oil resistant cable to a large extent oil resistant

min. installation temperature -5 °C min. installation temperature -5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Direct burialyes
Conductor materialbare copper
Conductor classclass 2, 7-wired construction
InsulationXLPE
Stranding unitpair
Strandinglayers
Core wrappingplastic foil
Material inner sheathPVC
Screenplastic coated aluminium foil + copper drain wire, tinned
Armourround or flat steel wires, galvanized
Sheathing materialPVC
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
UV-resistantyes
Oil-resistantyes
Permitted outer cable temperature, fixed-30 - +70 °C
Permitted outer cable temperature, in motion/during installation-5 - +50 °C
Bending radius, fixed installation10 x DA
Insulation resistance5000 MOhmxkm
Specific inductivity1 mH/km

For data communication with transmission rates up to 200 kBit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in earth.The types with blue outer sheath are suitable for intrinsically safe installation -Ex i- in hazardous areas. Core identification: black-white(-orange) with sequential numbering

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
101185 RE-2X(St)YSWAY-fl 01X2X0,5 SW IEC 332-3-24 15.0 178.0
101102 RE-2X(St)YSWAY-fl 02X2X0,5 SW IEC 332-3-24 30.0 270.0
101104 RE-2X(St)YSWAY-fl 04X2X0,5 SW IEC 332-3-24 46.0 345.0
101286 RE-2X(St)YSWAY-fl 06X2X0,5 SW IEC 332-3-24 70.0 415.0
101106 RE-2X(St)YSWAY-fl 12X2X0,5 SW IEC 332-3-24 130.0 625.0
101108 RE-2X(St)YSWAY-fl 24X2X0,5 SW IEC 332-3-24 250.0 1050.0
101110 RE-2X(St)YSWAY-fl 36X2X0,5 SW IEC 332-3-24 371.0 1315.0
101525 RE-2X(St)YSWAY-fl 01X2X0,75 SW IEC 332-3-24 25.0 203.0
101526 RE-2X(St)YSWAY-fl 02X2X0,75 SW IEC 332-3-24 47.0 310.0
101045 RE-2X(St)YSWAY-fl 12X2X0,75 SW IEC 332-3-24 185.0 805.0
101521 RE-2X(St)YSWAY-fl 16X2X0,75 SW IEC 332-3-24 245.0 945.0
101047 RE-2X(St)YSWAY-fl 24X2X0,75 SW IEC 332-3-24 365.0 1245.0
101073 RE-2X(St)YSWAY-fl 01X2X1,3 SW IEC 332-3-24 34.0 242.0
101079 RE-2X(St)YSWAY-fl 01X3X1,3 SW IEC 332-3-24 50.0 261.0
101074 RE-2X(St)YSWAY-fl 02X2X1,3 SW IEC 332-3-24 60.0 384.0
101187 RE-2X(St)YSWAY-fl 02X3X1,3 SW IEC 332-3-24 86.0 450.0
101075 RE-2X(St)YSWAY-fl 04X2X1,3 SW IEC 332-3-24 114.0 479.0
101076 RE-2X(St)YSWAY-fl 08X2X1,3 SW IEC 332-3-24 218.0 721.0
101179 RE-2X(St)YSWAY-fl 10X2X1,3 SW IEC 332-3-24 251.0 1206.0
101077 RE-2X(St)YSWAY-fl 12X2X1,3 SW IEC 332-3-24 322.0 1093.0
101271 RE-2X(St)YSWAY-fl 16X2X1,3 SW IEC 332-3-24 426.0 1270.0
101181 RE-2X(St)YSWAY-fl 20X2X1,3 SW IEC 332-3-24 494.3 2064.0
101078 RE-2X(St)YSWAY-fl 24X2X1,3 SW IEC 332-3-24 684.0 1779.0
101260 RE-2X(St)YSWAY-fl 01X2X1,5 SW IEC 332-3-24 39.0 254.0
101641 RE-2X(St)YSWAY-fl 01X3X1,5 SW IEC 332-3-24 55.0 298.0
101336 RE-2X(St)YSWAY-fl 02X2X1,5 SW IEC 332-3-24 72.1 402.0
101338 RE-2X(St)YSWAY-fl 20X2X1,5 SW IEC 332-3-24 605.0 1715.0
101183 RE-2X(St)YSWAY-fl 02X2X2,5 SW IEC 332-3-24 101.0 571.0
101186 RE-2X(St)YSWAY-fl 01X2X0,5 BL IEC 332-3-24 15.0 178.0
101103 RE-2X(St)YSWAY-fl 02X2X0,5 BL IEC 332-3-24 30.0 270.0
101105 RE-2X(St)YSWAY-fl 04X2X0,5 BL IEC 332-3-24 46.0 345.0
101287 RE-2X(St)YSWAY-fl 06X2X0,5 BL IEC 332-3-24 70.0 415.0
101107 RE-2X(St)YSWAY-fl 12X2X0,5 BL IEC 332-3-24 130.0 625.0
101109 RE-2X(St)YSWAY-fl 24X2X0,5 BL IEC 332-3-24 250.0 1050.0
101111 RE-2X(St)YSWAY-fl 36X2X0,5 BL IEC 332-3-24 371.0 1315.0
101527 RE-2X(St)YSWAY-fl 01X2X0,75 BL IEC 332-3-24 25.0 203.0
101528 RE-2X(St)YSWAY-fl 02X2X0,75 BL IEC 332-3-24 47.0 310.0
101149 RE-2X(St)YSWAY-fl 12X2X0,75 BL IEC 332-3-24 185.0 805.0
101523 RE-2X(St)YSWAY-fl 16X2X0,75 BL IEC 332-3-24 245.0 945.0
101046 RE-2X(St)YSWAY-fl 24X2X0,75 BL IEC 332-3-24 365.0 1245.0
101150 RE-2X(St)YSWAY-fl 01X3X1,3 BL IEC 332-3-24 50.0 261.0
101152 RE-2X(St)YSWAY-fl 02X2X1,3 BL IEC 332-3-24 60.0 384.0
101188 RE-2X(St)YSWAY-fl 02X3X1,3 BL IEC 332-3-24 86.0 450.0
101153 RE-2X(St)YSWAY-fl 04X2X1,3 BL IEC 332-3-24 114.0 479.0
101155 RE-2X(St)YSWAY-fl 08X2X1,3 BL IEC 332-3-24 218.0 721.0
101180 RE-2X(St)YSWAY-fl 10X2X1,3 BL IEC 332-3-24 251.0 1206.0
101156 RE-2X(St)YSWAY-fl 12X2X1,3 BL IEC 332-3-24 322.0 1093.0
101272 RE-2X(St)YSWAY-fl 16X2X1,3 BL IEC 332-3-24 426.0 1270.0
101182 RE-2X(St)YSWAY-fl 20X2X1,3 BL IEC 332-3-24 494.3 2064.0
101157 RE-2X(St)YSWAY-fl 24X2X1,3 BL IEC 332-3-24 684.0 1779.0
101261 RE-2X(St)YSWAY-fl 01X2X1,5 BL IEC 332-3-24 39.0 254.0
101335 RE-2X(St)YSWAY-fl 02X2X1,5 BL IEC 332-3-24 72.1 402.0
101337 RE-2X(St)YSWAY-fl 20X2X1,5 BL IEC 332-3-24 605.0 1715.0
101184 RE-2X(St)YSWAY-fl 02X2X2,5 BL IEC 332-3-24 101.0 571.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.