FRNC flexible cable NHXSGAFHXÖ

NHXSGAFHXÖ
flame retardant acc. IEC 60332-1-2 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 120 °C min. installation temperature -40 °C installation in free air without UV-protection (cable UV-resistant)

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 120 °C max. permitted temperature at conductor 120 °C

min. installation temperature -40 °C min. installation temperature -40 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardEN 50264-3-1
Conductor materialtinned copper
Conductor classclass 5 = fine stranded
Insulationpolyurethane elastomer EI 107
Sheathing materialcross-linked elastomer EM 104
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Oil-resistantEN 60811-2-1
Ozone-resistantyes
Maximum permitted conductor temperature120 °C
Permitted outer cable temperature, fixed-40 - +90 °C
Permitted outer cable temperature, in motion/during installation-40 - +90 °C
Bending radius, fixed installation4 x DA
Bending radius, moving application10 x DA

These cables are intended for use in railway rolling stock as fixed wiring, or connection where limited flexing in operation is encountered, they may be used both in- and outdoors, e.g. flexible between car floor and bogies. They are also usable for unfused connections in switchgear and distribution boards up to 1000 V (DIN VDE 0100-520 and DIN VDE 0660-500) and in accumulator circuits (DIN 5510 part 5).

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.