Including 1% procurement surcharge. No responsibility for the information!
+++ 24.11.2017 + AL 215.81 + CU 595.34 +++ 23.11.2017 + AL 217.19 + CU 598.52 +++ 22.11.2017 + AL 215.65 + CU 595.88 +++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

FRNC power cable (N)HXCH FE180/E30 plus

(N)HXCH FE180/E30 plus
cable with circuit integrity 30 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable conform to Low Voltage directive

cable with circuit integrity 30 min cable with circuit integrity 30 min

cable with function maintainance 180 min cable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

cable with VDE-certification cable with VDE-certification

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0266
VDEyes
Conductor materialbare copper
Conductor classclass 1 = solid
InsulationFRNC-compound HI1
Concentric conductorCu
Sheathing materialFRNC-compound HM1
Colour outer sheathorange
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Fire-resistantFE 180
Circuit integrityE30
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-5 - +70 °C
Bending radius, fixed installation12 x DA

Cable with concentric conductor for installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30).

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
015045 (N)HXCH FE180/E30 plus 02X1,5 RE/1,5 OR 52.0 165.0
015046 (N)HXCH FE180/E30 plus 02X2,5 RE/2,5 OR 80.0 215.0
015047 (N)HXCH FE180/E30 plus 02X4 RE/4 OR 123.0 295.0
015048 (N)HXCH FE180/E30 plus 02X6 RE/6 OR 183.0 385.0
015049 (N)HXCH FE180/E30 plus 02X10 RE/10 OR 312.0 580.0
015050 (N)HXCH FE180/E30 plus 03X1,5 RE/1,5 OR 66.0 195.0
015051 (N)HXCH FE180/E30 plus 03X2,5 RE/2,5 OR 104.0 245.0
015052 (N)HXCH FE180/E30 plus 03X4 RE/4 OR 161.0 350.0
015053 (N)HXCH FE180/E30 plus 03X6 RE/6 OR 240.0 460.0
015054 (N)HXCH FE180/E30 plus 03X10 RE/10 OR 408.0 680.0
015055 (N)HXCH FE180/E30 plus 04X1,5 RE/1,5 OR 81.0 220.0
015056 (N)HXCH FE180/E30 plus 04X2,5 RE/2,5 OR 128.0 290.0
015057 (N)HXCH FE180/E30 plus 04X4 RE/4 OR 200.0 415.0
015058 (N)HXCH FE180/E30 plus 04X6 RE/6 OR 297.0 535.0
015059 (N)HXCH FE180/E30 plus 04X10 RE/10 OR 504.0 815.0
015060 (N)HXCH FE180/E30 plus 05X1,5 RE/1,5 OR 95.0 255.0
015061 (N)HXCH FE180/E30 plus 05X2,5 RE/2,5 OR 152.0 330.0
015062 (N)HXCH FE180/E30 plus 05X4 RE/4 OR 238.0 470.0
015063 (N)HXCH FE180/E30 plus 05X6 RE/6 OR 346.0 625.0
015064 (N)HXCH FE180/E30 plus 05X10 RE/10 OR 576.0 955.0
015072 (N)HXCH FE180/E30 plus 07X1,5 RE/2,5 OR 133.0 310.0
015066 (N)HXCH FE180/E30 plus 07X2,5 RE/2,5 OR 200.0 500.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.