Medium voltage cable N2XS(F)2Y

N2XS(F)2Y
cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant) cable with VDE-certification

cable suitable for direct burial cable suitable for direct burial

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

min. installation temperature -20 °C min. installation temperature -20 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable with VDE-certification cable with VDE-certification

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0276-620
Direct burialyes
VDEyes
Conductor materialbare copper
Conductor classclass 2 = stranded
InsulationXLPE DIX8
Sheathing materialpolyethylene DMP2
Longitudinally watertightyes
Colour outer sheathblack
Flame-retardantno
UV-resistantyes
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed70 °C
Permitted outer cable temperature, in motion/during installation-20 - +70 °C
Bending radius, fixed installation15 x DA

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zero-halogen, yet not flame-retardant as defined under DIN VDE 0482-332-1. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
013261 N2XS(F)2Y 01X35/16 6/10 kV SW 518.0 820.0
011479 N2XS(F)2Y 01X50/16 6/10 kV SW 662.0 1150.0
011480 N2XS(F)2Y 01X70/16 6/10 kV SW 854.0 1400.0
011481 N2XS(F)2Y 01X95/16 6/10 kV SW 1094.0 1650.0
011482 N2XS(F)2Y 01X120/16 6/10 kV SW 1334.0 1900.0
011483 N2XS(F)2Y 01X150/25 6/10 kV SW 1723.0 2300.0
011484 N2XS(F)2Y 01X185/25 6/10 kV SW 2059.0 2650.0
011485 N2XS(F)2Y 01X240/25 6/10 kV SW 2587.0 3250.0
013271 (N)2XS(F)2Y 01X240/25 6/10 KV RT 2587.0 3250.0
011486 N2XS(F)2Y 01X300/25 6/10 kV SW 3163.0 3850.0
011487 N2XS(F)2Y 01X400/35 6/10 kV SW 4234.0 4800.0
011488 N2XS(F)2Y 01X500/35 6/10 kV SW 5194.0 5900.0
012224 N2XS(F)2Y 01X630/35 6/10 kV SW 6442.0 7014.0
014387 N2XS(F)2Y 1X800/35 6/10 kV SW 8094.0 8800.0
011546 N2XS(F)2Y 1X35/16 12/20 kV SW 518.0 1300.0
011489 N2XS(F)2Y 1X50/16 12/20 kV SW 662.0 1350.0
011490 N2XS(F)2Y 1X70/16 12/20 kV SW 854.0 1600.0
011317 N2XS(F)2Y 1X95/16 12/20 kV SW 1094.0 1900.0
011491 N2XS(F)2Y 1X120/16 12/20 kV SW 1334.0 2150.0
011492 N2XS(F)2Y 1X150/25 12/20 kV SW 1723.0 2500.0
011309 N2XS(F)2Y 1X185/25 12/20 kV SW 2059.0 2900.0
011493 N2XS(F)2Y 1X240/25 12/20 kV SW 2587.0 3500.0
011494 N2XS(F)2Y 1X300/25 12/20 kV SW 3163.0 4150.0
011495 N2XS(F)2Y 1X400/35 12/20 kV SW 4234.0 5100.0
011496 N2XS(F)2Y 1X500/35 12/20 kV SW 5194.0 6200.0
012225 N2XS(F)2Y 1X630/35 12/20 kV SW 6442.0 7365.0
013843 N2XS(F)2Y 1X800/35 12/20 kV SW 8094.0 8800.0
014083 N2XS(F)2Y 1X1000/35 12/20 kV SW 9994.0 10900.0
011516 N2XS(F)2Y 01X50/16 18/30 kV SW 662.0 1650.0
011517 N2XS(F)2Y 01X70/16 18/30 kV SW 854.0 1900.0
011526 N2XS(F)2Y 01X95/16 18/30 kV SW 1094.0 2150.0
011519 N2XS(F)2Y 01X120/16 18/30 kV SW 1334.0 2450.0
011520 N2XS(F)2Y 01X150/25 18/30 kV SW 1723.0 2750.0
011521 N2XS(F)2Y 01X185/25 18/30 kV SW 2059.0 3150.0
011972 N2XS(F)2Y 01X185/35 18/30 kV SW 2175.0 2955.0
011522 N2XS(F)2Y 01X240/25 18/30 kV SW 2587.0 3800.0
012216 N2XS(F)2Y 01X240/70 18/30 kV SW 3084.0 3786.0
011523 N2XS(F)2Y 01X300/25 18/30 kV SW 3163.0 4400.0
011524 N2XS(F)2Y 01X400/35 18/30 kV SW 4234.0 5450.0
011525 N2XS(F)2Y 01X500/35 18/30 kV SW 5194.0 6550.0
012226 N2XS(F)2Y 01X630/35 18/30 kV SW 6442.0 7803.0
013743 N2XS(F)2Y 01X800/35 18/30 kV SW 8094.0 9300.0
014084 N2XS(F)2Y 01X1000/35 18/30 kV SW 9994.0 11400.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.