Including 1% procurement surcharge. No responsibility for the information!
+++ 24.11.2017 + AL 215.81 + CU 595.34 +++ 23.11.2017 + AL 217.19 + CU 598.52 +++ 22.11.2017 + AL 215.65 + CU 595.88 +++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

Bus cable EIB/KNX PE

EIB/KNX PE
flame retardant acc. IEC 60332-1-2 cable suitable for direct burial min. installation temperature +5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

cable suitable for direct burial cable suitable for direct burial

min. installation temperature +5 °C min. installation temperature +5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Direct burialyes
Conductor materialbare copper
Conductor classclass 1 = solid
Insulationpolyethylene
Stranding unitpair
Strandinglayers
Screenplastic coated aluminium foil + solid copper drain wire
Sheathing materialpolyethylene
Colour outer sheathblack
UV-resistantyes
Permitted outer cable temperature, fixed-30 - +70 °C
Permitted outer cable temperature, in motion/during installation-5 - +50 °C
Bending radius, fixed installation7.5 x DA
Insulation resistance100 MOhmxkm
Nominal voltage U300 V
Maximum operating capacity100 nF/km
Test voltage0.8 kV

Due to the increased test voltage and the special marking the cable is designed as bus cable in the EIB/KNX facility control system according to EN 50090. For the Instabus itself is used only the red/black pair (transmission of 24 V supply voltage plus data packages), the second pair (white/yellow) is redundant.The cable may be installed on or under plaster, in ducts and buried in the ground.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
101639 FACAB EIB-Busleitung erdverlegbar 02X2X0,8 SW 21.0 75.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.