Self-supporting aerial power cable (N)Y(Zg)2Y

(N)Y(Zg)2Y
cable suitable for direct burial self-supporting cable max. permitted temperature at conductor 70 °C min. installation temperature +5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive

cable suitable for direct burial cable suitable for direct burial

self-supporting cable self-supporting cable

max. permitted temperature at conductor 70 °C max. permitted temperature at conductor 70 °C

min. installation temperature +5 °C min. installation temperature +5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Direct burialyes
Conductor materialbare copper
Conductor classclass 1 = solid
InsulationPVC DIV 4
Strength memberin outer sheath embedded glass yarns
Sheathing materialpolyethylene 2YM1
For outdoor useyes
Maximum permitted conductor temperature70 °C
Permitted outer cable temperature, fixed-20 - +70 °C
Permitted outer cable temperature, in motion/during installation5 - 70 °C
Bending radius, fixed installation10 x DA

The cable is designed for self-supporting aerial outdoor installation to support distances of up to 50 m. Suitable for supplying thinly populated or hard-to-reach areas, provisional building sites or for bridging difficult terrain. The high-tensile cable sheath can be regarded as a pulling aid so that the cable can also be pulled into pipes over long distances (gas and water pipelines).

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
031735 (N)YZG2Y-J 03X1,5 RE SW 43.0 160.0
031925 (N)YZG2Y-J 04X1,5 RE SW 58.0 180.0
032859 (N)YZG2Y-J 05X1,5 RE SW 72.0 230.0
031898 (N)YZG2Y-J 03X2,5 RE SW 72.0 195.0
031952 (N)YZG2Y-J 04X2,5 RE SW 96.0 240.0
031866 (N)YZG2Y-J 05X2,5 RE SW 120.0 240.0
032071 (N)YZG2Y-J 04X4 RE SW 154.0 350.0
031956 (N)YZG2Y-J 05X4 RE SW 192.0 410.0
032110 (N)YZG2Y-J 04X6 RE SW 230.0 440.0
031938 (N)YZG2Y-J 05X6 RE SW 288.0 520.0
032111 (N)YZG2Y-J 04X10 RE SW 384.0 630.0
032113 (N)YZG2Y-J 05X10 RE SW 480.0 780.0
032112 (N)YZG2Y-J 04X16 RE SW 614.0 880.0
034994 (N)YZG2Y-J 05X16 RE SW 768.0 1280.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.