(N)HXCH FE180/E30
cable with circuit integrity 30 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable conform to Low Voltage directive

cable with circuit integrity 30 min cable with circuit integrity 30 min

cable with function maintainance 180 min cable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

cable with VDE-certification cable with VDE-certification

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0266
VDEyes
Conductor materialbare copper
Conductor classclass 1, from 25 sqmm class 2
InsulationFRNC-compound HI1
Concentric conductorCu
Sheathing materialFRNC-compound HM1
Colour outer sheathorange
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Fire-resistantFE 180
Circuit integrityE30
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-5 - +70 °C
Bending radius, fixed installation12 x DA

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min.= IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 °C is approximately four times higher than at 20 °C and the current carrying capacity is reduced respectively.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
011505 NHXCH E30 02X1,5/1,5 RE OR 52.0 300.0
011506 NHXCH E30 02X2,5/2,5 RE OR 80.0 350.0
011507 NHXCH E30 02X4/4 RE OR 123.0 420.0
013253 NHXCH E30 02X6/6 RE OR 182.0 301.0
011278 NHXCH E30 03X1,5/1,5 RE OR 66.0 320.0
011215 NHXCH E30 03X2,5/2,5 RE OR 104.0 380.0
013753 NHXCH E30 03X4/4 RE OR 161.0 422.0
013754 NHXCH E30 03X6/6 RE OR 240.0 513.0
013755 NHXCH E30 03X10/10 RE OR 408.0 711.0
013756 NHXCH E30 03X16/16 RE OR 643.0 1033.0
013856 NHXCH E30 03X25/16 OR 902.0 1420.0
013857 NHXCH E30 03X50/25 RM OR 1723.0 2342.0
013858 NHXCH E30 03X70/35 RM OR 2410.0 3174.0
013859 NHXCH E30 03X95/50 RM OR 3296.0 4269.0
013860 NHXCH E30 03X120/70 RM OR 4236.0 5299.0
011831 NHXCH E30 03X150/70 RM OR 5100.0 7713.0
011832 NHXCH E30 03X185/95 RM OR 6383.0 8810.0
011280 NHXCH E30 04X1,5/1,5 RE OR 81.0 249.0
011281 NHXCH E30 04X2,5/2,5 RE OR 128.0 313.0
011282 NHXCH E30 04X4/4 RE OR 200.0 412.0
011226 NHXCH E30 04X6/6 RE OR 297.0 522.0
011224 NHXCH E30 04X10/10 RE OR 504.0 746.0
011181 NHXCH E30 04X16/16 OR 796.0 1119.0
011167 NHXCH E30 04X25/16 OR 1142.0 1583.0
011183 NHXCH E30 04X35/16 OR 1526.0 2002.0
011227 NHXCH E30 04X50/25 RM OR 2203.0 2700.0
011168 NHXCH E30 04X70/35 RM OR 3082.0 3838.0
011184 NHXCH E30 04X95/50 RM OR 4208.0 5181.0
011274 NHXCH E30 04X120/70 RM OR 5388.0 6500.0
011275 NHXCH E30 04X150/70 RM OR 6540.0 7950.0
011276 NHXCH E30 04X185/95 RM OR 8159.0 10130.0
011277 NHXCH E30 04X240/120 RM OR 10546.0 13190.0
011279 NHXCH E30 07X1,5/2,5 RE OR 133.0 500.0
011283 NHXCH E30 07X2,5/2,5 RE OR 200.0 600.0
011284 NHXCH E30 12X1,5/2,5 RE OR 205.0 700.0
011285 NHXCH E30 12X2,5/4 RM OR 334.0 900.0
014465 NHXCH E30 14X2,5/6 RE OR 403.0 646.0
013621 NHXCH E30 19X1,5/2,5 RE OR 310.0 913.0
013622 NHXCH E30 24X1,5/2,5 RE OR 383.0 1113.0
013820 NHXCH E30 19X1,5/4 RE OR 328.0 829.0
013821 NHXCH E30 24X1,5/6 RE OR 412.0 1093.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.