FRNC power cable (N)HXH FE180/E30

(N)HXH FE180/E30
cable with circuit integrity 30 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable conform to Low Voltage directive

cable with circuit integrity 30 min cable with circuit integrity 30 min

cable with function maintainance 180 min cable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

cable with VDE-certification cable with VDE-certification

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0266
VDEyes
Conductor materialbare copper
Conductor classclass 1, from 25 sqmm class 2
InsulationFRNC-compound HI1
Sheathing materialFRNC-compound HM1
Colour outer sheathorange
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Fire-resistantFE 180
Circuit integrityE30
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-5 - +70 °C
Bending radius, fixed installation12 x DA

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 °C is approximately four times higher than at 20 °C and the current carrying capacity is reduced respectively.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
011238 NHXH-O E30 01X4 RE OR 38.0 100.0
011240 NHXH-O E30 01X6 RE OR 58.0 120.0
011229 NHXH-O E30 01X10 RE OR 96.0 160.0
011232 NHXH-O E30 01X16 OR 154.0 200.0
011235 NHXH-O E30 01X25 RM OR 240.0 310.0
011237 NHXH-O E30 01X35 RM OR 336.0 410.0
011239 NHXH-O E30 01X50 RM OR 480.0 540.0
011241 NHXH-O E30 01X70 RM OR 672.0 740.0
011242 NHXH-O E30 01X95 RM OR 912.0 1020.0
011230 NHXH-O E30 01X120 RM OR 1152.0 1380.0
011231 NHXH-O E30 01X150 RM OR 1440.0 1560.0
011233 NHXH-O E30 01X185 RM OR 1776.0 1930.0
012034 NHXH-J E30 01X185 OR 1776.0 1930.0
011234 NHXH-O E30 01X240 RM OR 2304.0 2540.0
012198 NHXH-J E30 01X240 RM OR 2304.0 2540.0
011236 NHXH-O E30 01X300 RM OR 2880.0 3180.0
011243 NHXH-O E30 02X1,5 RE OR 29.0 190.0
011246 NHXH-O E30 02X2,5 RE OR 48.0 220.0
011248 NHXH-O E30 02X4 RE OR 77.0 270.0
011249 NHXH-O E30 02X6 RE OR 115.0 320.0
011244 NHXH-O E30 02X10 RE OR 192.0 430.0
011245 NHXH-O E30 02X16 OR 307.0 620.0
011247 NHXH-O E30 02X25 RM OR 480.0 900.0
011044 NHXH-J E30 03X1,5 RE OR 43.0 210.0
011171 NHXH-J E30 03X2,5 RE OR 72.0 260.0
011172 NHXH-J E30 03X4 RE OR 115.0 320.0
011194 NHXH-J E30 03X6 RE OR 173.0 400.0
011182 NHXH-J E30 03X10 RE OR 288.0 550.0
011185 NHXH-J E30 03X16 OR 461.0 790.0
011251 NHXH-J E30 03X25 RM OR 720.0 1150.0
011253 NHXH-J E30 03X35 RM OR 1008.0 1490.0
011255 NHXH-J E30 03X50 RM OR 1440.0 1980.0
011257 NHXH-J E30 03X70 RM OR 2016.0 2830.0
011252 NHXH-J E30 03X25/16 OR 874.0 1500.0
011254 NHXH-J E30 03X35/16 OR 1162.0 1800.0
011256 NHXH-J E30 03X50/25 RM OR 1680.0 2600.0
011258 NHXH-J E30 03X70/35 RM OR 2352.0 3400.0
011186 NHXH-J E30 03X95/50 RM OR 3216.0 4600.0
011269 NHXH-J E30 03X120/70 RM OR 4128.0 5700.0
011270 NHXH-J E30 03X150/70 RM OR 4992.0 6800.0
011271 NHXH-J E30 03X185/95 RM OR 6240.0 8500.0
011272 NHXH-J E30 03X240/120 RM OR 8064.0 11000.0
011188 NHXH-J E30 04X1,5 RE OR 58.0 240.0
011045 NHXH-J E30 04X2,5 RE OR 96.0 300.0
011217 NHXH-J E30 04X4 RE OR 154.0 390.0
011218 NHXH-J E30 04X6 RE OR 230.0 490.0
011219 NHXH-J E30 04X10 RE OR 384.0 670.0
011220 NHXH-J E30 04X16 OR 614.0 950.0
011221 NHXH-J E30 04X25 RM OR 960.0 1430.0
011189 NHXH-J E30 04X35 RM OR 1344.0 1890.0
011222 NHXH-J E30 04X50 RM OR 1920.0 2510.0
011196 NHXH-J E30 04X70 RM OR 2688.0 3650.0
011261 NHXH-J E30 04X95 RM OR 3648.0 4750.0
011259 NHXH-J E30 04X120 RM OR 4608.0 5910.0
011260 NHXH-J E30 04X150 RM OR 5760.0 7240.0
013794 NHXH-J E30 04X185 RM OR 7104.0 9704.0
011190 NHXH-J E30 05X1,5 RE OR 72.0 280.0
011046 NHXH-J E30 05X2,5 RE OR 120.0 354.0
011192 NHXH-J E30 05X4 RE OR 192.0 450.0
011193 NHXH-J E30 05X6 RE OR 288.0 570.0
011173 NHXH-J E30 05X10 RE OR 480.0 820.0
011195 NHXH-J E30 05X16 OR 768.0 1140.0
011262 NHXH-J E30 05X25 RM OR 1200.0 1710.0
012469 NHXH-J E30 05X35 OR 1680.0 2384.0
011047 NHXH-J E30 07X1,5 RE OR 101.0 330.0
013127 NHXH-J E30 10X1,5 RE OR 144.0 580.0
011214 NHXH-J E30 12X1,5 RE OR 173.0 500.0
011263 NHXH-J E30 19X1,5 RE OR 274.0 720.0
011265 NHXH-J E30 24X1,5 RE OR 346.0 890.0
011267 NHXH-J E30 30X1,5 RE OR 432.0 1090.0
011223 NHXH-J E30 07X2,5 RE OR 168.0 430.0
012838 NHXH-J E30 10X2,5 RE OR 240.0 522.0
011180 NHXH-J E30 12X2,5 RE OR 288.0 650.0
013662 NHXH-J E30 14X2,5 RE OR 336.0 676.0
011264 NHXH-J E30 19X2,5 RE OR 456.0 950.0
011266 NHXH-J E30 24X2,5 RE OR 576.0 1210.0
011268 NHXH-J E30 30X2,5 RE OR 720.0 1470.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.