Including 1% procurement surcharge. No responsibility for the information!
+++ 23.11.2017 + AL 217.19 + CU 598.52 +++ 22.11.2017 + AL 215.65 + CU 595.88 +++ 21.11.2017 + AL 215.01 + CU 586.20 +++ 20.11.2017 + AL 215.61 + CU 583.62 +++ 17.11.2017 + AL 218.63 + CU 588.20
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

FRNC power cable (N)HXCH FE180/E90

(N)HXCH FE180/E90
cable with circuit integrity 90 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable conform to Low Voltage directive

cable with circuit integrity 90 min cable with circuit integrity 90 min

cable with function maintainance 180 min cable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

cable with VDE-certification cable with VDE-certification

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0266
VDEyes
Conductor materialbare copper
Conductor classclass 1, from 25 sqmm class 2
InsulationFRNC-compound HI1
Concentric conductorCu
Sheathing materialFRNC-compound HM1
Colour outer sheathorange
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Fire-resistantFE 180
Circuit integrityE90
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-5 - +70 °C
Bending radius, fixed installation12 x DA

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 331). Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
013312 NHXCH E90 02X2,5/2,5 RE OR 87.0 370.0
011042 NHXCH E90 03X1,5/1,5 RE OR 66.0 348.0
011043 NHXCH E90 03X2,5/2,5 RE OR 104.0 410.0
011209 NHXCH E90 03X4/4 RE OR 161.0 500.0
011208 NHXCH E90 03X6/6 RE OR 240.0 614.0
011207 NHXCH E90 03X10/10 RE OR 408.0 830.0
011206 NHXCH E90 03X16/16 OR 643.0 1073.0
011205 NHXCH E90 03X25/16 OR 902.0 1450.0
011204 NHXCH E90 03X35/16 OR 1190.0 1798.0
011197 NHXCH E90 03X50/25 RM OR 1723.0 2394.0
011203 NHXCH E90 03X70/35 RM OR 2410.0 2796.0
011213 NHXCH E90 03X95/50 RM OR 3296.0 4434.0
011202 NHXCH E90 03X120/70 RM OR 4236.0 5534.0
011201 NHXCH E90 03X150/70 RM OR 5100.0 6546.0
011200 NHXCH E90 03X185/95 RM OR 6383.0 8303.0
011198 NHXCH E90 03X240/120 RM OR 8242.0 10605.0
010995 NHXCH E90 04X1,5/1,5 RE OR 81.0 398.0
010996 NHXCH E90 04X2,5/2,5 RE OR 128.0 470.0
010997 NHXCH E90 04X4/4 RE OR 200.0 578.0
010987 NHXCH E90 04X6/6 RE OR 297.0 726.0
010994 NHXCH E90 04X10/10 RE OR 504.0 983.0
010998 NHXCH E90 04X16/16 OR 796.0 1370.0
010999 NHXCH E90 04X25/16 OR 1142.0 1904.0
010993 NHXCH E90 04X35/16 OR 1526.0 2427.0
011000 NHXCH E90 04X50/25 RM OR 2203.0 3177.0
011001 NHXCH E90 04X70/35 RM OR 3082.0 4378.0
011002 NHXCH E90 04X95/50 RM OR 4208.0 5803.0
011003 NHXCH E90 04X120/70 RM OR 5388.0 7230.0
011004 NHXCH E90 04X150/70 RM OR 6540.0 8707.0
011005 NHXCH E90 04X185/95 RM OR 8159.0 10894.0
011006 NHXCH E90 04X240/120 RM OR 10546.0 13933.0
011747 NHXCH E90 05X2,5/2,5 RE OR 152.0 480.0
011749 NHXCH E90 05X4/4 RE OR 238.0 600.0
010988 NHXCH E90 07X1,5/2,5 RE OR 133.0 498.0
011007 NHXCH E90 07X2,5/2,5 RE OR 200.0 680.0
012739 NHXCH E90 10X1,5/2,5 RE OR 176.0 520.0
011008 NHXCH E90 12X1,5/2,5 RE OR 205.0 718.0
011009 NHXCH E90 12X2,5/4 RE OR 334.0 1050.0
011748 NHXCH E90 12X4/6 RE OR 528.0 1100.0
011210 NHXCH E90 24X1,5/6 RE OR 413.0 1305.0
011211 NHXCH E90 24X2,5/10 RE OR 696.0 1400.0
011212 NHXCH E90 30X1,5/6 RE OR 499.0 1519.0
011199 NHXCH E90 30X2,5/10 RE OR 840.0 1550.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.