Railway power cable GGSG

GGSG
flame retardant acc. IEC 60332-1-2 screened cable max. permitted temperature at conductor 90 °C cable conform to Low Voltage directive

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

screened cable screened cable

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Technical data
  • Item list
  • Application
  • Technical documents
Conductor materialbare copper
Conductor materialcopper, bare
Conductor classclass 5 = fine stranded
Insulationrubber EI7
Material inner sheathrubber EM7
Screencopper wires
Sheathing materialrubber EM7
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
Oil-resistantEN 60811-2-1
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-40 - +80 °C
Permitted outer cable temperature, in motion/during installation-25 - +80 °C
Bending radius, fixed installation6 x DA

For the power supply on the lines of S-Bahn trains operated with DC voltage for installation in dry, damp and wet rooms, outdoors, in pipes and ducts, underground. Feed and connecting cable for connection to conductor rail systems, where tight bending radii, vibration and vibration are required and difficult installation conditions may occur. The core insulation (1st insulating jacket) is protected by the 1st sheathing against mechanical stress and damage. Environmental influences are protected, so that further protection can be omitted when the screen is removed. Both the complete cable run as well as the inner part up to the first sheath fulfills the flame retardance for single cable according to DIN EN 60332-1-2. Both sheaths are oil resistant.
This cable is suitable for all standard terminations and connection components as well as for standardised vertical and horizontal connections.

In addition, the general specifications in DIN VDE 0298-3 also apply.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
011865 GGSG 01X300/95 1,8/3 kV RT 3904.0 4850.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.