LSOH wire with increased temperature range FABER® THERM 145 (single core)

FABER® THERM 145 (single core)
flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 145 °C min. installation temperature -35 °C cable conform to Low Voltage directive cable with GOST-certification

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

max. permitted temperature at conductor 145 °C max. permitted temperature at conductor 145 °C

min. installation temperature -35 °C min. installation temperature -35 °C

cable conform to Low Voltage directive cable conform to Low Voltage directive

cable with GOST-certification cable with GOST-certification

  • Technical data
  • Item list
  • Application
  • Technical documents
GOST/EACyes
Conductor materialtinned copper
Conductor classclass 5 = fine stranded
Insulationcross-linked polyolefin-copolymer
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
Ozone-resistantyes
Maximum permitted conductor temperature145 °C
Permitted outer cable temperature, fixed-55 - +145 °C
Permitted outer cable temperature, in motion/during installation-35 - +120 °C
Bending radius, fixed installation4 x DA
Bending radius, moving application6 x DA

This electron beam cross-linked, halogen-free, insulated wire is used for the connection of lights, heating units and machines in environments with increased temperatures. In addition to a long working life and a high permissible conductor temperature it also ensures an increased current carrying capacity in comparison to conventional cables. Not for installation on ladders or trays. Ship approvals (GL, DNV, LRS, BV) can be provided on request.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
041253 FABER THERM 145-SC 01X0,5 SW 5.0 8.0
041254 FABER THERM 145-SC 01X0,5 WS 5.0 8.0
041255 FABER THERM 145-SC 01X0,75 GE 7.2 11.0
041256 FABER THERM 145-SC 01X0,75 GN 7.2 11.0
041257 FABER THERM 145-SC 01X0,75 GG 7.2 11.0
041260 FABER THERM 145-SC 01X0,75 WS 7.2 11.0
041261 FABER THERM 145-SC 01X0,75 GR 7.2 11.0
041262 FABER THERM 145-SC 01X0,75 OR 7.2 11.0
041263 FABER THERM 145-SC 01X0,75 SW 7.2 11.0
041283 FABER THERM 145-SC 01X1 GG 10.0 14.0
041285 FABER THERM 145-SC 01X1,5 BR 14.4 21.0
041286 FABER THERM 145-SC 01X1,5 DB 14.4 21.0
041287 FABER THERM 145-SC 01X1,5 GE 14.4 21.0
041288 FABER THERM 145-SC 01X1,5 GN 14.4 21.0
041264 FABER THERM 145-SC 01X0,75 VL 7.2 11.0
041265 FABER THERM 145-SC 01X0,75 DB 7.2 11.0
041266 FABER THERM 145-SC 01X0,75 BR 7.2 11.0
041267 FABER THERM 145-SC 01X1 SW 10.0 14.0
041289 FABER THERM 145-SC 01X1,5 GR 14.4 21.0
041290 FABER THERM 145-SC 01X1,5 HB 14.4 21.0
041291 FABER THERM 145-SC 01X1,5 RT 14.4 21.0
041292 FABER THERM 145-SC 01X1,5 VL 14.4 21.0
041293 FABER THERM 145-SC 01X1,5 WS 14.4 21.0
041268 FABER THERM 145-SC 01X1,5 GG 14.4 20.0
041269 FABER THERM 145-SC 01X1,5 SW 14.4 21.0
041294 FABER THERM 145-SC 01X1,5 OR 14.4 21.0
041295 FABER THERM 145-SC 01X2,5 BR 24.0 31.0
041296 FABER THERM 145-SC 01X2,5 DB 24.0 31.0
041270 FABER THERM 145-SC 01X2,5 GG 24.0 32.0
041297 FABER THERM 145-SC 01X2,5 GN 24.0 32.0
041299 FABER THERM 145-SC 01X2,5 RT 24.0 31.0
041271 FABER THERM 145-SC 01X2,5 SW 24.0 32.0
041300 FABER THERM 145-SC 01X2,5 WS 24.0 32.0
041272 FABER THERM 145-SC 01X4 SW 38.4 48.0
041301 FABER THERM 145-SC 01X4 GG 38.4 48.0
041273 FABER THERM 145-SC 01X6 SW 58.0 76.0
041303 FABER THERM 145-SC 01X6 GG 58.0 69.0
041274 FABER THERM 145-SC 01X10 SW 96.0 120.0
041304 FABER THERM 145-SC 01X10 GG 96.0 120.0
041275 FABER THERM 145-SC 01X16 GG 154.0 181.0
041276 FABER THERM 145-SC 01X16 SW 154.0 181.0
041305 FABER THERM 145-SC 01X16 HB 154.0 181.0
041277 FABER THERM 145-SC 01X25 SW 240.0 265.0
041278 FABER THERM 145-SC 01X35 GG 336.0 369.0
041279 FABER THERM 145-SC 01X35 SW 336.0 386.0
041280 FABER THERM 145-SC 01X50 SW 480.0 580.0
041306 FABER THERM 145-SC 01X50 GG 480.0 580.0
041307 FABER THERM 145-SC 01X70 GG 672.0 734.0
041281 FABER THERM 145-SC 01X70 SW 672.0 765.0
041282 FABER THERM 145-SC 01X95 SW 912.0 1040.0
041309 FABER THERM 145-SC 01X120 SW 1152.0 1273.0
041310 FABER THERM 145-SC 01X150 SW 1440.0 1582.0
041311 FABER THERM 145-SC 01X150 GG 1440.0 1582.0
041312 FABER THERM 145-SC 01X185 SW 1776.0 2100.0
041313 FABER THERM 145-SC 01X240 SW 2304.0 2526.0
041341 FABER THERM 145-SC 01X300 SW 2880.0 2872.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289