2% Rabatt auf Online-Bestellungen
Details
flame retardant acc. IEC 60332-1-2 cable to a large extent oil resistant max. permitted temperature at conductor 90 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0510521X95/16 KON 6/10 kV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
0512861X120/16 KON 6/10 kV RD
on request
AufmachungPreis
0513461X150/25 KON 6/10 kV RD
on request
AufmachungPreis
0513021X185/25 KON 6/10 kV RD
on request
AufmachungPreis
0512681X240/25 KON 6/10 kV RD
on request
AufmachungPreis
0514911X300/25 KON 6/10 kV RD
on request
AufmachungPreis
053382(N)TMCGCWOEU 1X630/35KON 6/10KV RD
in stock
AufmachungPreis
0511691X240 6/10 kV RD
on request
AufmachungPreis
0511031X300 6/10 kV RD
on request
AufmachungPreis
053134(N)TMCGCWOEU 1X400/35 KON 8.7/15KV RD
on request
AufmachungPreis
0517471X25/16 KON 12/20 kV RD
on request
AufmachungPreis
0511191X35/16 KON 12/20 kV RD
on request
AufmachungPreis
0512771X50/16 KON 12/20 kV RD
in stock
AufmachungPreis
0514461X70/16 KON 12/20 kV RD
in stock
AufmachungPreis
0511351X95/16 KON 12/20 kV RD
in stock
AufmachungPreis
0515301X120/16 KON 12/20 kV RD
in stock
AufmachungPreis
0513001X150/25 KON 12/20 kV RD
in stock
AufmachungPreis
0512661X185/25 KON 12/20 kV RD
in stock
AufmachungPreis
0512921X240/25 KON 12/20 kV RD
on request
AufmachungPreis
0514751X300/25 KON 12/20 kV RD
on request
AufmachungPreis
0515491X500/35 KON 12/20 kV RD
on request
AufmachungPreis
0516491X630/35 KON 12/20 kV RD
on request
AufmachungPreis
0525741X35/16 KON 18/30 kV RD
on request
AufmachungPreis
0517401X95/16 KON 18/30 kV RD
on request
AufmachungPreis
0517411X120/16 KON 18/30 kV RD
on request
AufmachungPreis
0516741X150/25 KON 18/30 kV RD
on request
AufmachungPreis
0529621X185/25 KON 18/30 kV RD
on request
AufmachungPreis
0516351X240/25 KON 18/30 kV RD
on request
AufmachungPreis
0515421X300/25 KON 18/30 kV RD
on request
AufmachungPreis
0530721X500/35 KON 18/30 kV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Electrical field control inner and outer semiconducting rubber layer
Arrangement of protective conductors copper spiral shield
Sheathing material rubber (CR) 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +60 °C
Bending radius, fixed installation 6 x Ø
Bending radius, moving application 10 x Ø
Core diameter 10.1 mm
Number of cores 1
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Single core cables are used in short lengths, e.g. for the connection of switchgear cubicles and for the connection of mobile transformer substations. When laying and during operation, care should be taken to protect them from excessive mechanical stress. The outer semi-conducting layer must not be heated before removal.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator