Including 1% procurement surcharge. No responsibility for the information!
+++ 17.11.2017 + AL 218.63 + CU 588.20 +++ 16.11.2017 + AL 215.27 + CU 580.37 +++ 15.11.2017 + AL 217.13 + CU 594.03 +++ 14.11.2017 + AL 220.03 + CU 593.90 +++ 13.11.2017 + AL 219.28 + CU 596.70
Your language: DE | EN
Discover the diversity of Faber Kabel.

Discover the diversity of Faber Kabel.

More cable is impossible.

Flexible medium voltage cable (N)TMCGCWOEU

(N)TMCGCWOEU
flame retardant acc. IEC 60332-1-2 cable to a large extent oil resistant max. permitted temperature at conductor 90 °C min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant)

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

cable to a large extent oil resistant cable to a large extent oil resistant

max. permitted temperature at conductor 90 °C max. permitted temperature at conductor 90 °C

min. installation temperature -20 °C min. installation temperature -20 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

  • Technical data
  • Item list
  • Application
  • Technical documents
StandardVDE 0250-813 (with ref. to)
Conductor materialtinned copper
Conductor classclass 5 = fine stranded
Insulationrubber 3GI3
Electrical field controlinner and outer semiconducting rubber layer
Arrangement of protective conductorscopper spiral shield on each core
Torsion+/- 25 °/m
Sheathing materialrubber (CR) 5GM3
Colour outer sheathred
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
UV-resistantyes
Oil-resistantEN 60811-2-1
Ozone-resistantyes
For outdoor useyes
Maximum permitted conductor temperature90 °C
Permitted outer cable temperature, fixed-40 - +80 °C
Permitted outer cable temperature, in motion/during installation-25 - +60 °C
Bending radius, fixed installation6 x DA
Bending radius, moving application15 x DA

Single core cables are used in short lengths, e.g. for the connection of switchgear cubicles and for the connection of mobile transformer substations. When laying and during operation, care should be taken to protect them from excessive mechanical stress. The outer semi-conducting layer must not be heated before removal.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
051052 (N)TMCGCWOEU 01X95/16 KON 6/10 kV RT 1066.0 1590.0
051286 (N)TMCGCWOEU 01X120/16 KON 6/10 kV RT 1452.0 1880.0
051346 (N)TMCGCWOEU 01X150/25 KON 6/10 kV RT 1740.0 2320.0
051302 (N)TMCGCWOEU 01X185/25 KON 6/10 kV RT 2078.0 2670.0
051268 (N)TMCGCWOEU 01X240/25 KON 6/10 kV RT 2640.0 3310.0
051491 (N)TMCGCWOEU 01X300/25 KON 6/10 kV RT 3120.0 3690.0
051169 (N)TMCGEWOEU 01X240 6/10 kV RT 2304.0 3100.0
051103 (N)TMCGEWOEU 01X300 6/10 kV RT 2880.0 3750.0
051119 (N)TMCGCWOEU 01X35/16 KON 12/20 kV RT 576.0 970.0
051277 (N)TMCGCWOEU 01X50/16 KON 12/20 kV RT 712.0 1200.0
051446 (N)TMCGCWOEU 01X70/16 KON 12/20 kV RT 912.0 1440.0
051135 (N)TMCGCWOEU 01X95/16 KON 12/20 kV RT 1145.0 1690.0
051300 (N)TMCGCWOEU 01X150/25 KON 12/20 kV RT 1740.0 2510.0
051266 (N)TMCGCWOEU 01X185/25 KON 12/20 kV RT 2083.0 2810.0
051292 (N)TMCGCWOEU 01X240/25 KON 12/20 kV RT 2640.0 3540.0
051475 (N)TMCGCWOEU 01X300/25 KON 12/20 kV RT 3309.0 4417.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.