Heat resistant cable 2GTL

2GTL
flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-1-2 cable with low smoke IEC 61034 cable halogen-free cable to a large extent oil resistant max. permitted temperature at conductor 180 °C installation in free air without UV-protection (cable UV-resistant)

flame retardant acc. IEC 60332-3-24 flame retardant acc. IEC 60332-3-24

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

cable with low smoke IEC 61034 cable with low smoke IEC 61034

cable halogen-free cable halogen-free

cable to a large extent oil resistant cable to a large extent oil resistant

max. permitted temperature at conductor 180 °C max. permitted temperature at conductor 180 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

  • Technical data
  • Item list
  • Application
  • Technical documents
Conductor materialtinned copper
Conductor classclass 5 = fine stranded
Insulationsilicone rubber
Coveringsynthetic yarn, varnish coating with PUR
Flame-retardantVDE 0482-266-2-4/IEC 60332-3-24 (Kat. C)
Smoke densityDIN EN 61034/IEC 61034
Halogen-freeDIN EN 50267/IEC 60754
UV-resistantyes
Ozone-resistantyes
Maximum permitted conductor temperature180 °C
Permitted outer cable temperature, fixed-50 - +180 °C
Bending radius, fixed installation6 x DA

This connection cable is primarily used where great flexibility is required and a great thermal stress provided, e.g. transformers, generators, engines etc. For installation indoors and in cable ducts for power plant, industry and distribution networks. The halogen-free coating lends the cable good non-slip properties and abrasion-resistance as well as a very good resistance to transformer oil and light fuel oil.

Item numberItem nameAl
kg/km
Cu
kg/km
Weight
kg/km
036142 2GTL 01X70 1,1/1,9 kV GE 672.0 752.0
036433 2GTL 01X95 1,1/1,9 kV GE 912.0 1009.0
036143 2GTL 01X150 1,1/1,9 kV GE 1440.0 1557.0
036498 2GTL 01X185 1,1/1,9 kV GE 1776.0 1903.0
036144 2GTL 01X240 1,1/1,9 kV GE 2304.0 2453.0
036465 2GTL 01X16 3,3/4,2 kV BR 153.6 236.0
036434 2GTL 01X185 3,3/4,2 kV BR 1776.0 1921.0
036264 2GTL 01X10 13,8/15 kV SW 96.0 277.0
036326 2GTL 01X16 13,8/15 kV SW 154.0 346.0
036435 2GTL 01X25 13,8/15 kV SW 240.0 454.0
036331 2GTL 01X35 13,8/15 kV SW 336.0 565.0
036298 2GTL 01X50 13,8/15 kV SW 480.0 729.0
036436 2GTL 01X70 13,8/15 kV SW 672.0 957.0
036437 2GTL 01X95 13,8/15 kV SW 912.0 1219.0
036578 2GTL 01X120 13,8/15 kV SW 1152.0 1470.0
036579 2GTL 01X150 13,8/15 kV SW 1440.0 1769.0
036323 2GTL 01X185 13,8/15 kV SW 1776.0 2123.0
036460 2GTL 01X240 13,8/15 kV SW 2304.0 2665.0

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.