Power cable NYY-O 04X10 RE SW

Item number 010102

NYY-O 04X10 RE SW
flame retardant acc. IEC 60332-1-2 cable suitable for direct burial max. permitted temperature at conductor 70 °C min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable with EAC-approval cable conform to Low Voltage directive

flame retardant acc. IEC 60332-1-2 flame retardant acc. IEC 60332-1-2

cable suitable for direct burial cable suitable for direct burial

max. permitted temperature at conductor 70 °C max. permitted temperature at conductor 70 °C

min. installation temperature -5 °C min. installation temperature -5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable for use in water cable for use in water

cable with VDE-certification cable with VDE-certification

cable with EAC-approval cable with EAC-approval

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Datasheet
  • Application
  • Technical documents
StandardVDE 0276-603
Conductor materialbare copper
Conductor classclass 1, from 25 sqmm class 2
InsulationPVC DIV 4
Sheathing materialPVC DMV 5
Colour outer sheathblack
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
UV-resistantyes
Maximum permitted conductor temperature70 °C
Permitted outer cable temperature, fixed70 °C
Permitted outer cable temperature, in motion/during installation-5 - +70 °C
Nominal voltage Uo600 V
Nominal voltage U1000 V
Maximum permitted operating voltage in three-phase systems1.2 kV
Test voltage4 kV
Conductor shaperound
Conductor shape (Faber)RE
Number of cores4
Nominal cross section10 mm²
Conductor resistance1.83 Ohm/km
Insulation wall thickness1 mm
Ampacity in air (30 °C)59 A
Ampacity in ground (20 °C)79 A
Short-circuit current (1 s)1.15 kA
Specific inductivity0.301 mH/km
Wall thickness of sheath1.8 mm
Bending radius, fixed installation219.6 mm
Outer diameter approx.18.3 mm
Colour of outer sheathblack
Tensile strength (during installation)2000 N
colourblack

For fixed installation indoors, outdoors, in the ground, in water and in conrete.

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber Kabel has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.