Power cable NAYCWY 04X70 SE/35 SW

Item number 090153

NAYCWY 04X70 SE/35 SW
cable suitable for direct burial max. permitted temperature at conductor 70 °C min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable conform to Low Voltage directive

cable suitable for direct burial cable suitable for direct burial

max. permitted temperature at conductor 70 °C max. permitted temperature at conductor 70 °C

min. installation temperature -5 °C min. installation temperature -5 °C

installation in free air without UV-protection (cable UV-resistant) installation in free air without UV-protection (cable UV-resistant)

cable for use in water cable for use in water

cable with VDE-certification cable with VDE-certification

cable conform to Low Voltage directive cable conform to Low Voltage directive

  • Datasheet
  • Application
  • Technical documents
StandardVDE 0276-603
Conductor materialaluminium
InsulationPVC DIV 4
Concentric conductorCu
Sheathing materialPVC DMV 5
Colour outer sheathblack
Flame-retardantVDE 0482-332-1-2/IEC 60332-1-2
UV-resistantyes
For outdoor useyes
Maximum permitted conductor temperature70 °C
Permitted outer cable temperature, fixed70 °C
Permitted outer cable temperature, in motion/during installation-5 - +70 °C
Nominal voltage Uo600 V
Nominal voltage U1000 V
Maximum permitted operating voltage in three-phase systems1.2 kV
Test voltage4 kV
Core identificationcolours acc. to HD 308; more than 5 cores: numbers
Conductor shape (Faber)SE
Number of cores4
Nominal cross section70 mm²
Conductor resistance0.443 Ohm/km
Insulation wall thickness1.4 mm
Ampacity in air (30 °C)155 A
Ampacity in ground (20 °C)186 A
Short-circuit current (1 s)5.32 kA
Specific inductivity0.262 mH/km
Wall thickness of sheath2.1 mm
Bending radius, fixed installation420 mm
Outer diameter approx.35 mm
Tensile strength (during installation)8400 N
colourblack

For fixed installation indoors, outdoors, in the ground, in water and in conrete.

All images shown here are for illustrations and product reference purposes only.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 47 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-0
Fax +49 681 97 11-289

Newsletter.