Item number 011069
flame retardant acc. IEC 60332-3-24
cable with low smoke IEC 61034
cable halogen-free
max. permitted temperature at conductor 90 °C
installation in free air only with UV-protection (cable not UV-resistant)
cable with VDE-certification
cable conform to Low Voltage directive
Standard | VDE 0276-604 |
Conductor material | copper, bare |
Conductor class | class 1, from 25 sqmm class 2 |
Insulation | XLPE 2XI1 |
Sheathing material | FRNC-compound HM4 |
Flame-retardant | DIN EN 50266-2-4/VDE 0482-266-2-4/IEC 60332-3-24 (cat. C) |
Smoke density | DIN EN 61034/IEC 61034 |
Halogen-free | DIN EN 50267/IEC 60754 |
Maximum permitted conductor temperature | 90 °C |
Permitted outer cable temperature, fixed | -30 - +70 °C |
Permitted outer cable temperature, in motion/during installation | -5 - +70 °C |
Bending radius, fixed installation | 15 x DA |
Nominal voltage Uo | 600 V |
Protective conductor | no |
Nominal voltage U | 1000 V |
Maximum permitted operating voltage in three-phase systems | 1.2 kV |
Test voltage | 4 kV |
Core identification | colours acc. to HD 308; more than 5 cores: numbers |
Conductor shape | round |
Conductor shape (Faber) | RM |
Number of cores | 2 |
Nominal cross section | 25 mm² |
Conductor resistance | 0.727 Ohm/km |
Insulation wall thickness | 0.9 mm |
Ampacity in air (30 °C) | 133 A |
Short-circuit current (1 s) | 3.58 kA |
Bending radius, fixed installation | 276 mm |
Conductor class | class 2 = stranded |
Outer diameter approx. | 23 mm |
Colour of outer sheath | black |
Tensile strength (during installation) | 2500 N |
Cable shape | round |
colour | black |
Zero-halogen, low-smoke power cable with improved flame-retardance. For fixed installation indoors, in air as well as in concrete, but not for direct burial in the ground or application in water.
All images shown here are for illustrations and product reference purposes only.